  "alert_number": "0033/07",
  "url": "https://recallarchive.com/alert/0033-07",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-11742",
  "safety_gate_published": "2007-01-18",
  "weekly_report": {
    "year": 2007,
    "week": 2,
    "date": "2007-01-19"
  },
  "category": "Electrical appliances and equipment",
  "product": "Cord extension set",
  "brand_as_notified": "Contra",
  "brands": [
    {
      "name": "Contra",
      "url": "https://recallarchive.com/brand/contra"
    }
  ],
  "name": null,
  "model": "Type: RTD30M3EL; EAN: 5 414385 045030",
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": null,
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "The product poses a serious risk of electric shock because the cross-sectional areas of the wires of the cord extension set do not meet the requirements: the cross-sectional area of the protective safety earth wire (green-yellow wire) is only about 0,2 mm². Therefore, the protective safety earth wire of the cord extension set may break in case of a fault condition occurred in a product connected to the extension cord set. In this case the protective safety earthing does not work and it causes a risk of electric shock.The product does not comply with the Low Voltage Directive and the relevant standards.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Recall from consumers ordered by the authority",
      "operator": "Other",
      "ordered": true,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Other\nCategory of measure(s): Recall from consumers ordered by the authority\nDate of entry into force: Unknown",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Finland",
  "country_of_origin": "Unknown",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [],
    "models": [
      "Type: RTD30M3EL; EAN: 5 414385 045030"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}