  "alert_number": "0129/08",
  "url": "https://recallarchive.com/alert/0129-08",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-13187",
  "safety_gate_published": "2008-01-31",
  "weekly_report": {
    "year": 2008,
    "week": 4,
    "date": "2008-02-01"
  },
  "category": "Lighting equipment",
  "product": "Table lamp \"Present Light\" in the shape of a star",
  "brand_as_notified": "Moon",
  "brands": [
    {
      "name": "MOON",
      "url": "https://recallarchive.com/brand/moon"
    }
  ],
  "name": null,
  "model": "Present Light, GB7000.11-1999.",
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "Portable table lamps (230V/25W) with plastic lampshade in the shape of a star. Protection Class II-design. The lamp housing is also made of plastic with an E14 lamp holder. Dimensions: (255x290x100) mm (HxWxD).",
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "The product poses a risk of electric shock because:- the luminaire has no cord anchorage and the mains cables conductors are therefore insufficiently protected against tension and twisting. Nor does the mains switch have any strain relief, - the nominal cross-section of the mains cable is less than 0.5 mm² (the required measurement is 0.75mm²), which does not provide sufficient mechanical strength,- wires with basic insulation can be touched where they enter the lamp housing,- all inscriptions required by the standard, such as the manufacturer's data, the rated voltage, the Protection Class II symbol, the type or order number and the rated power of the bulb are missing.The product does not comply with the Low Voltage Directive and with the relevant European standard EN 60598.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Withdrawal from the market ordered by the authorities",
      "operator": "Other",
      "ordered": true,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Other\nCategory of measure(s): Withdrawal from the market ordered by the authorities.\nDate of entry into force: Unknown",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Germany",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [],
    "models": [
      "Present Light, GB7000.11-1999."
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}