  "alert_number": "0141/08",
  "url": "https://recallarchive.com/alert/0141-08",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-13199",
  "safety_gate_published": "2008-02-07",
  "weekly_report": {
    "year": 2008,
    "week": 5,
    "date": "2008-02-08"
  },
  "category": "Lighting equipment",
  "product": "Recessed luminaires with halogen lamps",
  "brand_as_notified": "Huayi Lighting",
  "brands": [
    {
      "name": "Huayi Lighting",
      "url": "https://recallarchive.com/brand/huayilighting"
    }
  ],
  "name": null,
  "model": "MS-1001 and MS-01XSY",
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "The metal-covered lights include a silver metal frame, a GX5.3 ceramic lampholder for connecting bi-pin SELV halogen lamps. A terminal block was supplied with the MS-101 type luminaire. This type cannot be adjusted, while the MS-01XSY type can be adjusted in approx. 30°. Main parts of product: GX5.3 lampholder (\"DX-106 25V 4A VDE CE\"), terminal block (\"W6 380V N D FI UL CE\").Technical specifications: 220/230 V~, 50/60 Hz, MR16 Max. 50 W, F-mark.",
  "production_dates": null,
  "risk_type": "Electric shock, Fire",
  "risk": "The notified products pose a risk of:- electric shock since the basic insulated parts (SELV lampholder connected to 230V and the wires connected to the lampholder), and the pins of the light source are accessible;- fire because the consumer will presumably use a bi-pin SELV(-Safety of Extra Low Voltage -) halogen lamp designed for SELV lampholder and connect it to the mains power supply (230V).In addition, the symbols indicating the rated voltage and the classification are missing from the data plate. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Withdrawal from the market and recall from consumers ordered by the authorities",
      "operator": "Other",
      "ordered": true,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Other\nCategory of measure(s): Withdrawal from the market and recall from consumers ordered by the authorities.\nDate of entry into force: Unknown",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Hungary",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [],
    "models": [
      "MS-1001 and MS-01XSY"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",