  "alert_number": "0592/07",
  "url": "https://recallarchive.com/alert/0592-07",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-12297",
  "safety_gate_published": "2007-06-21",
  "weekly_report": {
    "year": 2007,
    "week": 24,
    "date": "2007-06-22"
  },
  "category": "Construction products",
  "product": "Window-balcony",
  "brand_as_notified": "Velux",
  "brands": [
    {
      "name": "Velux",
      "url": "https://recallarchive.com/brand/velux"
    }
  ],
  "name": null,
  "model": "GDL P19",
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "Window-balconies GDL P19 sold from 1 June 2005 to 16 April 2007. The window-balconies affected have the following information placed on the information plate, which is located on the upper frame: GDL P19 and one of the following codes: AR05, AR06, AR07, AR08, AR09, AR10, AR11, AR12, AS01, AS02, AS03, AS04, AS05, AS06, AS07, AS08, AS09, AS10, AS11, AS12, AT01, AT02, AT03 or AT04.",
  "production_dates": null,
  "risk_type": "Injuries",
  "risk": "The two screws used to attach the side railings are 1.6 mm too short, which means that they cannot be fixed securely to the nuts. When the window-balcony is opened and closed, the screws, which are on each side of the upper part of the side railings, can become loose and detach, rendering one (or both) side railings unsafe. The barrier is therefore inadequate, with the consequent risk of injury. As long as the nut is fastened/fitted to the screw, the structure of the railing remains intact but becomes loose. Despite being unstable the strength of the railing is unchanged. If one of the screws and nuts became detached, the side railing would remain unattached to the lower element.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Voluntary corrective actions taken by the importer",
      "operator": "Other",
      "ordered": false,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator taking notified measure(s): Other\nCategory of measure(s): Voluntary corrective actions taken by the importer\nDate of entry into force: Unknown",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Portugal",
  "country_of_origin": "Unknown",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [],
    "models": [
      "GDL P19"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}