  "alert_number": "0600/09",
  "url": "https://recallarchive.com/alert/0600-09",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-15196",
  "safety_gate_published": "2009-05-07",
  "weekly_report": {
    "year": 2009,
    "week": 17,
    "date": "2009-05-08"
  },
  "category": "Electrical appliances and equipment",
  "product": "Fan heater",
  "brand_as_notified": "Sapir",
  "brands": [
    {
      "name": "Sapir",
      "url": "https://recallarchive.com/brand/sapir"
    }
  ],
  "name": null,
  "model": "SP-1970-BA",
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "A heater with a built-in fan for use in bathrooms. Technical parameters: 2000W, 230V~, 50Hz; with marking for class II protection against electric shock.",
  "production_dates": null,
  "risk_type": "Electric shock, Fire",
  "risk": "The product poses a risk of fire because: - during testing with a locked motor rotor, the plastic turbine of the fan ignites after 18 seconds, - the appliance is not fire resistant and the fire does not go out 30 seconds after flame extinction; and a risk of electric shock because the wires of the supply cord have a cross-sectional area of 0.75 mm² which is less than the requirement (1.0 mm²).The product does not comply with the Low Voltage Directive and the relevant European standard EN 60335.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Sales ban and withdrawal from the market ordered by the authorities",
      "operator": "Other",
      "ordered": true,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Other\nCategory of measure(s): Sales ban and withdrawal from the market ordered by the authorities.\nDate of entry into force: Unknown",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Bulgaria",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [],
    "models": [
      "SP-1970-BA"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",