  "alert_number": "0641/06",
  "url": "https://recallarchive.com/alert/0641-06",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-11459",
  "safety_gate_published": "2006-10-05",
  "weekly_report": {
    "year": 2006,
    "week": 39,
    "date": "2006-10-06"
  },
  "category": "Electrical appliances and equipment",
  "product": null,
  "brand_as_notified": null,
  "brands": [],
  "name": null,
  "model": null,
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "Digital multimeter \"SOLID\".Type/model: RE830A; EAN 8 595092 106072.Description: Electronic measuring equipment in a yellow enclosure (Class of protection II) supplied with two measuring probes for the measurement of CAT II and a digital display 31/2 dig., A safe range use: direct-voltage up to 1000V, direct-current up to 200mA, alternating-voltage up to 750V.",
  "production_dates": null,
  "risk_type": "Electric shock, Fire",
  "risk": "This product poses a risk of electric shock and fire because:- the equipment does not meet the protection requirements in a single fault condition (dangerous live parts);- the measured creepage distances do not meet the requirements on double insulation; - the minimum reinforced insulation which is required between the enclosure and live parts is not provided;- the protection against electric shock is not secured at the test probes; - after the testing the excessive prolongation of the cable occurred and the insulation moved in the terminal by more than 2 mm.-marking - the pictures (pictograms) are not in compliance with the standard. This product does not comply with the Low Voltage Directive and the LVD standards.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Sales ban ordered by the authority. Date of entry into force: Unknown",
      "operator": "Other",
      "ordered": true,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Other\nCategory of measure(s): Sales ban ordered by the authority. Date of entry into force: Unknown",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Czechia",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [],
    "models": []
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}