  "alert_number": "0664/07",
  "url": "https://recallarchive.com/alert/0664-07",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-12369",
  "safety_gate_published": "2007-07-12",
  "weekly_report": {
    "year": 2007,
    "week": 27,
    "date": "2007-07-13"
  },
  "category": "Machinery",
  "product": "Electric soldering-iron",
  "brand_as_notified": "PROFI",
  "brands": [
    {
      "name": "Profi",
      "url": "https://recallarchive.com/brand/profi"
    }
  ],
  "name": null,
  "model": "Unknown",
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "The following technical parameters are indicated on the electric soldering-iron: 220V, 240V, 60W. The supply cord is bifilar 2X0.5mm2.",
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "The product poses a serious risk of electric shock because:- accessible metal parts of the device are not earthed (the earth terminal and earth cable are missing),. the lower and higher limits of working voltage of the electric soldering-iron are not marked in the range of notified parameters,- the instruction for use does not include a text that in case of damaged cord the manufacturer must replaced it. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60335.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Sales ban, withdrawal from the market ordered by the authorities",
      "operator": "Other",
      "ordered": true,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Other\nCategory of measure(s): Sales ban, withdrawal from the market ordered by the authorities\nDate of entry into force: Unknown",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Bulgaria",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [],
    "models": [
      "Unknown"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}