  "alert_number": "0802/06",
  "url": "https://recallarchive.com/alert/0802-06",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-11618",
  "safety_gate_published": "2006-12-07",
  "weekly_report": {
    "year": 2006,
    "week": 48,
    "date": "2006-12-08"
  },
  "category": "Electrical appliances and equipment",
  "product": "Heat-sealing glue gun",
  "brand_as_notified": null,
  "brands": [],
  "name": null,
  "model": null,
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "Category: Electrical appliancesProduct: Heat-sealing glue gunBrand: Taipan Tools (on the package)Type/number of model: model HJG-053 (on the packaging)",
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "This product poses a serious risk of electric shock because:- the insulation does not comply with the requirements of the standard on both double and reinforced insulation;(the pins of the plug are insulated insufficiently and the insulation of the conductors of the supply cord does not comply with the requirements on double or reinforced insulation);- when the plug is partly inserted into a socket-outlet, it is possible to touch the pins of the plug by the test finger;- the cross-sectional area of the conductors of the cord is insufficient;- the instructions for the use are not provided in the Czech language.These products do not comply with the Low Voltage Directive and the LVD standard.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Withdrawal from the market ordered by the authority",
      "operator": "Other",
      "ordered": true,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Other\nCategory of measure(s): Withdrawal from the market ordered by the authority\nDate of entry into force: Unknown",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Czechia",
  "country_of_origin": "Unknown",
  "alert_type": "Consumer",