  "alert_number": "0876/08",
  "url": "https://recallarchive.com/alert/0876-08",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-13927",
  "safety_gate_published": "2008-08-14",
  "weekly_report": {
    "year": 2008,
    "week": 32,
    "date": "2008-08-15"
  },
  "category": "Electrical appliances and equipment",
  "product": "Travel charger",
  "brand_as_notified": "Unknown",
  "brands": [],
  "name": null,
  "model": "CLT-760A",
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "Black switching travel charger packed in a box with names of importer and producer.",
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "The product poses a risk of electric shock because there is no sufficient insulation between primary and secondary windings. Clearances, creepage distances and insulation between the mains part and the output connector do not comply with the requirements for double insulation.The product does not comply with the Low Voltage Directive and the relevant European standard EN 60950.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Withdrawal from the market and recall from consumers by the importer ordered by the authorities Date of entry into force: Unknown",
      "operator": "Other",
      "ordered": true,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Other\nCategory of measure(s): Withdrawal from the market and recall from consumers by the importer ordered by the authorities Date of entry into force: Unknown",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Slovakia",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [],
    "models": [
      "CLT-760A"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}