  "alert_number": "1125/08",
  "url": "https://recallarchive.com/alert/1125-08",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-14174",
  "safety_gate_published": "2008-10-09",
  "weekly_report": {
    "year": 2008,
    "week": 40,
    "date": "2008-10-10"
  },
  "category": "Electrical appliances and equipment",
  "product": "Switching mode power supply",
  "brand_as_notified": "EuroCASE",
  "brands": [
    {
      "name": "EuroCASE",
      "url": "https://recallarchive.com/brand/eurocase"
    }
  ],
  "name": null,
  "model": "ATX-450 JSP, P#2007-09, 0718014014, ATX 2,03AAA(P4), E401-9",
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "Power supply for computers sold without packaging, user's manual and installation guide.",
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "The product poses a risk of electric shock because: - construction of the converter does not comply with the requirements for distance between primary and secondary windings for reinforced insulation, - the capacitors in primary circuits do not comply, - values for clearances and creepage distances are less than the minimum required,- the length of conductors enables by-passing of double insulation in the case of connector release and a possibility of presence of mains voltage on exit connectors, - material of connector is not resistant against excessive heat, - the product did not pass the tensile test for basic insulation between cover and mains plugs. The product does not comply with the Low Voltage Directive and the relevant European standards EN 60950, EN 55022, EN 55024 and EN 61000.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Voluntary withdrawal from the market and recall from consumers by the distributor",
      "operator": "Other",
      "ordered": false,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator taking notified measure(s): Other\nCategory of measure(s): Voluntary withdrawal from the market and recall from consumers by the distributor.\nDate of entry into force: Unknown",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Slovakia",
  "country_of_origin": "Unknown",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [],
    "models": [
      "ATX-450 JSP, P#2007-09, 0718014014, ATX 2,03AAA(P4), E401-9"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}