  "alert_number": "1153/08",
  "url": "https://recallarchive.com/alert/1153-08",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-14201",
  "safety_gate_published": "2008-10-16",
  "weekly_report": {
    "year": 2008,
    "week": 41,
    "date": "2008-10-17"
  },
  "category": "Lighting chains",
  "product": "Lighting chain - 20L LED light",
  "brand_as_notified": "Royal",
  "brands": [
    {
      "name": "Royal",
      "url": "https://recallarchive.com/brand/royal"
    }
  ],
  "name": null,
  "model": "Model no: 0620, 20L-43x32,5x5 cm,",
  "batch": null,
  "barcode_as_notified": "6924524300122",
  "barcodes": [
    "6924524300122"
  ],
  "description": "The product is a lighting chain including a frame in the form of a star with 20 connected non-replaceable LEDs, 20 resistors and a rectifying unit. Mains plug with inscription: \"2.5 A 250 V~CE+VDE; rectifying unit with inscription: LX-01 24V-240V 50/60Hz 1.0A +CE; resistors of 620 ohm; LEDs without marking, mains cable without marking. Technical parameters: 230 V~, 50 Hz, 4,6 W; 3 V;  0,02A; 0,06W; Class II, IP20.",
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "The product poses a risk of electric shock because : - there is only basic insulation on the soldered connections of the light sources, - the cross-section area of the core is too small, - the cable inlet of the rectifying unit has sharp edges, - the cord anchorage is missing in the rectifying unit. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Withdrawal from the market and recall from consumers ordered by the authorities",
      "operator": "Other",
      "ordered": true,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Other\nCategory of measure(s): Withdrawal from the market and recall from consumers ordered by the authorities.\nDate of entry into force: Unknown",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Hungary",
  "country_of_origin": "Unknown",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [
      "6924524300122"
    ],
    "batches": [],
    "models": [
      "Model no: 0620, 20L-43x32,5x5 cm,"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}