  "alert_number": "1269/08",
  "url": "https://recallarchive.com/alert/1269-08",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-14316",
  "safety_gate_published": "2008-10-30",
  "weekly_report": {
    "year": 2008,
    "week": 43,
    "date": "2008-10-31"
  },
  "category": "Electrical appliances and equipment",
  "product": "Hair clipper - Proclipper",
  "brand_as_notified": "Sanusy Austria",
  "brands": [
    {
      "name": "Sanusy Austria",
      "url": "https://recallarchive.com/brand/sanusyaustria"
    }
  ],
  "name": null,
  "model": "SN-3999, Bar code: 9191439003500",
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "The appliance is made of black and grey plastic. Main components of the appliance: mains plug (6 A; 250 V~; + marks of approval); mains cable (H03VVH2-F; 2x0.75mm2; VDE); mains switch (SAN LIAN; KC 888; 6 A; 250 V; AC). Technical specification: 230 V~; 50 Hz; 35 W; Class II.",
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "This product poses a risk of electric shock because: - the basic insulated parts are accessible, - the dimensions of the mains plug are non-compliant,- the wires are not protected against detachment. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60335.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Withdrawal from the market and recall from consumers ordered by the authorities",
      "operator": "Other",
      "ordered": true,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Other\nCategory of measure(s): Withdrawal from the market and recall from consumers ordered by the authorities.\nDate of entry into force: Unknown",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Hungary",
  "country_of_origin": "Unknown",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [],
    "models": [
      "SN-3999, Bar code: 9191439003500"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}