  "alert_number": "1356/07",
  "url": "https://recallarchive.com/alert/1356-07",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-13053",
  "safety_gate_published": "2008-01-03",
  "weekly_report": {
    "year": 2007,
    "week": 51,
    "date": "2008-01-04"
  },
  "category": "Lighting equipment",
  "product": "Lighting chain",
  "brand_as_notified": "Royal",
  "brands": [
    {
      "name": "Royal",
      "url": "https://recallarchive.com/brand/royal"
    }
  ],
  "name": null,
  "model": "1. 0601-100L-6M (model No on the packaging: 0601) Bar code: 6924524300122,      2. 0604-240L-13M (model No on the packaging: 0604) Bar code: 6924524300122.",
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "The lighting chain contains 100/240 series-parallel connected incandescent lamps with resistor bridge. The flashing unit controls the four parallel circuits. Main parts of the luminaire: bipolar plug with inscription: \"2.5 A 250 V~ VDE CE\"; flashing unit with inscription: \"FLASHER CONTROL UNIT 230V AC 50HZ 0.83A CE TÜV EMC PRESS\". Technical parameters: 230 V~, 50 Hz, 63,7 W, Class II, IP20, bulbs: 9 V, 0,07A.",
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "The product poses a serious risk of electric shock because:- the insulation is not sufficient (only single insulation cover the connections), - flashover occurred at 3050V/2800V when tested the insulation, - the cross section of the core is too small, - the length of the cable is too short (0,9/0,91 m), - the cable inlets are sharp, - the wires are not secured against loosening, they can get damaged. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Sales ban and withdrawal from the market and recall from consumers ordered by the authorities",
      "operator": "Other",
      "ordered": true,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Other\nCategory of measure(s): Sales ban and withdrawal from the market and recall from consumers ordered by the authorities.\nDate of entry into force: Unknown",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Hungary",
  "country_of_origin": "Unknown",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [],
    "models": [
      "1. 0601-100L-6M (model No on the packaging: 0601) Bar code: 6924524300122, 2. 0604-240L-13M (model No on the packaging: 0604) Bar code: 6924524300122."
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}