  "alert_number": "1792/10",
  "url": "https://recallarchive.com/alert/1792-10",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-18052",
  "safety_gate_published": "2010-12-02",
  "weekly_report": {
    "year": 2010,
    "week": 48,
    "date": "2010-12-03"
  },
  "category": "Electrical appliances and equipment",
  "product": "Balance board stand - Wii Balance Board Stand",
  "brand_as_notified": "Blue Ocean",
  "brands": [
    {
      "name": "Blue Ocean",
      "url": "https://recallarchive.com/brand/blueocean"
    }
  ],
  "name": null,
  "model": "Model number is BOA025. UK.RB. Barcode - 4020628997304.",
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "Balance board stand which includes a power supply. The risk is posed by the power supply only.",
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "The power supply poses a risk of electric shock because the connection to the live and neutral pins of the plug is made purely by solder. In the event of the solder failing on one of the pins a short circuit could occur. There is excess wire on the low voltage side of the transformer; if one of these wires were to become loose they could touch the input side of the board. In addition, the transformer does not provide sufficient insulation between the primary and secondary circuits. The plug face and pin sizes are considered to be too small. The product does not comply with the Low Voltage Directive (LVD) and with the relevant European standard EN 60950.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Voluntary withdrawal from the market and recall from consumers",
      "operator": "Other",
      "ordered": false,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator taking notified measure(s): Other\nCategory of measure(s): Voluntary withdrawal from the market and recall from consumers.\nDate of entry into force: Unknown",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "United Kingdom",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [],
    "models": [
      "Model number is BOA025. UK.RB. Barcode - 4020628997304."
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}