  "alert_number": "A12/00036/20",
  "url": "https://recallarchive.com/alert/a12-00036-20",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/10000368",
  "safety_gate_published": "2020-02-13",
  "weekly_report": {
    "year": 2020,
    "week": 3,
    "date": "2020-01-17"
  },
  "category": "Electrical appliances and equipment",
  "product": "Steamer",
  "brand_as_notified": "Steam Magic",
  "brands": [
    {
      "name": "Steam Magic",
      "url": "https://recallarchive.com/brand/steammagic"
    }
  ],
  "name": "Handy Steamer",
  "model": "BI-55",
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "Domestic steam iron fitted with a C18 appliance inlet. The item was supplied with a separate mains to C13 supply cord.",
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "The supply cord is not protected against excessive flexing and can consequently split, exposing live parts. A user could consequently receive an electric shock. The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60335-2-3.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Withdrawal of the product from the market",
      "operator": "Distributor",
      "ordered": true,
      "from": "17 Oct 2019"
    },
    {
      "measure": "Recall of the product from end users",
      "operator": "Distributor",
      "ordered": false,
      "from": null
    },
    {
      "measure": "Withdrawal of the product from the market",
      "operator": "Distributor",
      "ordered": false,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Distributor\nCategory of measure(s): Withdrawal of the product from the market\nDate of entry into force: 17/10/2019\nType of economic operator taking notified measure(s): Distributor\nCategory of measure(s): Recall of the product from end users\nDate of entry into force: Unknown\nType of economic operator taking notified measure(s): Distributor\nCategory of measure(s): Withdrawal of the product from the market\nDate of entry into force: Unknown",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "United Kingdom",
  "country_of_origin": "Unknown",