  "alert_number": "A12/00088/21",
  "url": "https://recallarchive.com/alert/a12-00088-21",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/10002782",
  "safety_gate_published": "2021-04-08",
  "weekly_report": {
    "year": 2021,
    "week": 4,
    "date": "2021-01-29"
  },
  "category": "Pressure equipment/vessels",
  "product": "SODA-CLUB (SodaStream) cylinder for  CO 2 425 gr",
  "brand_as_notified": "AGA Linde Gas, CBF Drinkit, SodaStream, Vikingsoda, Watercompany, Ölbolaget",
  "brands": [
    {
      "name": "AGA Linde Gas",
      "url": "https://recallarchive.com/brand/agalindegas"
    },
    {
      "name": "CBF Drinkit",
      "url": "https://recallarchive.com/brand/cbfdrinkit"
    },
    {
      "name": "SodaStream",
      "url": "https://recallarchive.com/brand/sodastream"
    },
    {
      "name": "Vikingsoda",
      "url": "https://recallarchive.com/brand/vikingsoda"
    },
    {
      "name": "Watercompany",
      "url": "https://recallarchive.com/brand/watercompany"
    },
    {
      "name": "Ölbolaget",
      "url": "https://recallarchive.com/brand/olbolaget"
    }
  ],
  "name": "The labelling varies due which filling operator handled it latest as it is an exchange system.",
  "model": "The valve in question is engraved with \"SODA-CLUB (CO 2) CE0038 L- 250 BAR\" and production date.",
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "L- type valve SODA-CLUB (CO 2). The valve is mounted on SODACLUB (Sodastream) cylinders for carbon dioxide (CO 2) 425 gram.(This notification does not concern N-type valves or other type of valves mounted on cylinders from SodaStream.)",
  "production_dates": null,
  "risk_type": "Injuries",
  "risk": "The upper part of the L-type valve may release and get ejected due to the internal pressure in the cylinder causing injuries to the user. No testing is performed. The product does not comply with the requirements of the Transportable Pressure Equipment Directive or the requirements of the Pressure Equipment Directive.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Withdrawal of the product from the market",
      "operator": "Distributor",
      "ordered": false,
      "from": "24 Nov 2020"
    },
    {
      "measure": "Stop of sales, Withdrawal of the product from the market",
      "operator": "Distributor",
      "ordered": false,
      "from": "18 Dec 2020"
    },
    {
      "measure": "Withdrawal of the product from the market",
      "operator": "Distributor",
      "ordered": false,
      "from": "18 Dec 2020"
    },
    {
      "measure": "Withdrawal of the product from the market",
      "operator": "Distributor",
      "ordered": false,
      "from": "15 Dec 2020"
    },
    {
      "measure": "Withdrawal of the product from the market",
      "operator": "Manufacturer",
      "ordered": false,
      "from": "18 Dec 2020"
    }
  ],
  "measures_as_published": "Type of economic operator taking notified measure(s): Distributor\nCategory of measure(s): Withdrawal of the product from the market\nDate of entry into force: 24/11/2020\nType of economic operator taking notified measure(s): Distributor\nCategory of measure(s): Stop of sales, Withdrawal of the product from the market\nDate of entry into force: 18/12/2020\nType of economic operator taking notified measure(s): Distributor\nCategory of measure(s): Withdrawal of the product from the market\nDate of entry into force: 18/12/2020\nType of economic operator taking notified measure(s): Distributor\nCategory of measure(s): Withdrawal of the product from the market\nDate of entry into force: 15/12/2020\nType of economic operator taking notified measure(s): Manufacturer\nCategory of measure(s): Withdrawal of the product from the market\nDate of entry into force: 18/12/2020",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Sweden",
  "country_of_origin": "Israel",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [],
    "models": [
      "The valve in question is engraved with \"SODA-CLUB (CO 2) CE0038 L- 250 BAR\" and production date."
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}