  "alert_number": "A12/00913/20",
  "url": "https://recallarchive.com/alert/a12-00913-20",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/10001509",
  "safety_gate_published": "2020-06-22",
  "weekly_report": {
    "year": 2020,
    "week": 26,
    "date": "2020-06-26"
  },
  "category": "Protective equipment",
  "product": "Particle filter mask",
  "brand_as_notified": "BKJ",
  "brands": [
    {
      "name": "BKJ",
      "url": "https://recallarchive.com/brand/bkj"
    }
  ],
  "name": "KN95 Protective mask",
  "model": "9001",
  "batch": "Batches: 2020-4-26 / 2020-4-28 / 2020-4-30Production series: BKJ202004",
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "KN95 protective respiratory filtration half-face mask, corresponding to category FFP2 according to EN 149.",
  "production_dates": null,
  "risk_type": "Health risk / other",
  "risk": "The particle/filter retention of the material is insufficient (measured value ≤ 94 %), the mask does not properly adapt to the face resulting in a insufficient total filtration capacity (Measured value  ≤ 68 %).Consequently, an excessive amount of particles or microorganisms might pass through the mask, increasing the risk of infection if not combined with additional protective measures. The product does not comply with the Personal Protective Equipment Regulation.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Ban on the marketing of the product and any accompanying measures",
      "operator": "Importer",
      "ordered": true,
      "from": "26 May 2020"
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Importer\nCategory of measure(s): Ban on the marketing of the product and any accompanying measures\nDate of entry into force: 26/05/2020",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Belgium",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [
      "Batches: 2020-4-26 / 2020-4-28 / 2020-4-30",
      "Production series: BKJ202004"
    ],
    "models": [
      "9001"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}