  "alert_number": "A12/01156/22",
  "url": "https://recallarchive.com/alert/a12-01156-22",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/10006577",
  "safety_gate_published": "2022-09-11",
  "weekly_report": {
    "year": 2022,
    "week": 32,
    "date": "2022-08-12"
  },
  "category": "Protective equipment",
  "product": "Particle filter mask",
  "brand_as_notified": "Placide",
  "brands": [
    {
      "name": "Placide",
      "url": "https://recallarchive.com/brand/placide"
    }
  ],
  "name": "FFP2 R D Wiederverwendbare Maske mit Nano-Technologie",
  "model": "RY-CR1",
  "batch": null,
  "barcode_as_notified": "42607115800004260711580055426071158010942607115801164260711580123",
  "barcodes": [
    "4260711580000",
    "4260711580055",
    "4260711580109",
    "4260711580116",
    "4260711580123"
  ],
  "description": "Reusable respiratory protective half-face mask with adjustable ear loops and cotton outer layer, available in at least 7 diff. colours (incl. black, white, pink, blue, green, each w. different barcode), with \"FFP2\" and the CE mark printed on. Product sold online, in particular via Amazon and eBay.",
  "production_dates": null,
  "risk_type": "Health risk / other",
  "risk": "After washing, the particle/filter retention capacity of the material reduces significantly (measured values: as low as 69%). Furthermore, the product contains erroneous indications regarding its use, reducing its protective function. Consequently, the product does not fulfil the health and safety requirements; thus, even if combined with other recommended measures, it may not properly protect. The product does not comply with the Personal Protective Equipment Regulation nor with the European standard EN 149.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Stop of sales",
      "operator": "Importer",
      "ordered": false,
      "from": "26 Jul 2022"
    },
    {
      "measure": "Warning consumers of the risks",
      "operator": "Importer",
      "ordered": false,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator taking notified measure(s): Importer\nCategory of measure(s): Stop of sales\nDate of entry into force: 26/07/2022\nType of economic operator taking notified measure(s): Importer\nCategory of measure(s): Warning consumers of the risks\nDate of entry into force: Unknown",
  "company_recall_code": null,
  "recall_page": "https://mask24.net/pages/sicherheitshinweis-179179",
  "online_marketplaces": [
    "Amazon",
    "eBay"
  ],
  "notifying_country": "Germany",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [
      "4260711580000",
      "4260711580055",
      "4260711580109",
      "4260711580116",
      "4260711580123"
    ],
    "batches": [],
    "models": [
      "RY-CR1"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}