  "alert_number": "A12/01237/20",
  "url": "https://recallarchive.com/alert/a12-01237-20",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/10001906",
  "safety_gate_published": "2020-09-10",
  "weekly_report": {
    "year": 2020,
    "week": 38,
    "date": "2020-09-18"
  },
  "category": "Lighting chains",
  "product": "Lighting chain",
  "brand_as_notified": "Pm series",
  "brands": [
    {
      "name": "Pm Series",
      "url": "https://recallarchive.com/brand/pmseries"
    }
  ],
  "name": "Lampki Choinkowe Diody / LED karácsonyfa fényei",
  "model": null,
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "Lighting chain with 20 non-replaceable, colourful LED lamps with plastic rod-shaped casing.",
  "production_dates": null,
  "risk_type": "Burns, Electric shock, Fire",
  "risk": "The cable is not properly anchored and is too thin. The accessible wires have inadequate insulation. The dimensions of the mains plug are substantially less than required. The cable could overheat, leading to burns or fire. The user could touch accessible live parts, which may cause an electric shock. The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Recall of the product from end users",
      "operator": "Distributor",
      "ordered": true,
      "from": "24 Apr 2020"
    },
    {
      "measure": "Withdrawal of the product from the market",
      "operator": "Distributor",
      "ordered": true,
      "from": "24 Apr 2020"
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Distributor\nCategory of measure(s): Recall of the product from end users\nDate of entry into force: 24/04/2020\nType of economic operator to whom the measure(s) were ordered: Distributor\nCategory of measure(s): Withdrawal of the product from the market\nDate of entry into force: 24/04/2020",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Hungary",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [],
    "models": []
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}