  "alert_number": "A12/01779/20",
  "url": "https://recallarchive.com/alert/a12-01779-20",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/10002677",
  "safety_gate_published": "2020-12-11",
  "weekly_report": {
    "year": 2020,
    "week": 51,
    "date": "2020-12-18"
  },
  "category": "Electrical appliances and equipment",
  "product": "Hair dryer",
  "brand_as_notified": "Gemei",
  "brands": [
    {
      "name": "Gemei",
      "url": "https://recallarchive.com/brand/gemei"
    }
  ],
  "name": "PROFESSIONAL HAIR DRYER",
  "model": "Model: GM-1737, N0.19221-15 (on the label)",
  "batch": null,
  "barcode_as_notified": "1819221888815 (on the label)6 957952 217373 (on the packaging)",
  "barcodes": [
    "1819221888815",
    "6957952217373"
  ],
  "description": "Pink and white foldable hair dryer.",
  "production_dates": null,
  "risk_type": "Burns, Electric shock, Fire",
  "risk": "The hair dryer does not have a thermal cut-out device. The plastic material of the casing is combustible. The hair dryer can overheat and catch fire during use causing burns to the user.The distance between the heater and the safety grille is less than required. The dimensions of the mains plug are substantially less than required and the live pins of the mains supply plug are accessible during connecting. The user may touch the live parts and receive an electric shock. The product does not comply with the requirements of the Low Voltage Directive and the relevant European Standard EN 60335.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Withdrawal of the product from the market",
      "operator": "Distributor",
      "ordered": true,
      "from": "4 Dec 2020"
    },
    {
      "measure": "Recall of the product from end users",
      "operator": "Distributor",
      "ordered": true,
      "from": "4 Dec 2020"
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Distributor\nCategory of measure(s): Withdrawal of the product from the market\nDate of entry into force: 04/12/2020\nType of economic operator to whom the measure(s) were ordered: Distributor\nCategory of measure(s): Recall of the product from end users\nDate of entry into force: 04/12/2020",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Hungary",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [
      "1819221888815 (on the label)",
      "6 957952 217373 (on the packaging)"
    ],
    "batches": [],
    "models": [
      "Model: GM-1737, N0.19221-15 (on the label)"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}