  "alert_number": "A12/03052/24",
  "url": "https://recallarchive.com/alert/a12-03052-24",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/10091860",
  "safety_gate_published": "2024-10-29",
  "weekly_report": {
    "year": 2024,
    "week": 44,
    "date": "2024-11-01"
  },
  "category": "Lighting chains",
  "product": "Lighting chain",
  "brand_as_notified": null,
  "brands": [],
  "name": "Merry Christmas 100 LED",
  "model": "100M85",
  "batch": null,
  "barcode_as_notified": "6902204579136",
  "barcodes": [
    "6902204579136"
  ],
  "description": "Lighting chain of green colour, which contains 100 LEDs of non-replaceable light sources. The product is sold with a device for changing lighting modes.",
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "Due to insufficient mechanical strength of the product, an insufficient cross-section of the wires, and an insufficient protection against moisture, the user may access live parts and receive an electric shock. The product does not comply with the requirements of the Low Voltage Directive and the European standards EN 60598-1 and EN 60598-2-20.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Recall of the product from end users",
      "operator": "Retailer",
      "ordered": false,
      "from": null
    },
    {
      "measure": "Warning consumers of the risks",
      "operator": "Retailer",
      "ordered": false,
      "from": null
    },
    {
      "measure": "Withdrawal of the product from the market",
      "operator": "Retailer",
      "ordered": false,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator taking notified measure(s): Retailer\nCategory of measure(s): Recall of the product from end users\nDate of entry into force: Unknown\nType of economic operator taking notified measure(s): Retailer\nCategory of measure(s): Warning consumers of the risks\nDate of entry into force: Unknown\nType of economic operator taking notified measure(s): Retailer\nCategory of measure(s): Withdrawal of the product from the market\nDate of entry into force: Unknown",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Slovakia",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [
      "6902204579136"
    ],
    "batches": [],
    "models": [
      "100M85"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}