  "alert_number": "A12/03700/24",
  "url": "https://recallarchive.com/alert/a12-03700-24",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/10092467",
  "safety_gate_published": "2024-12-12",
  "weekly_report": {
    "year": 2024,
    "week": 51,
    "date": "2024-12-20"
  },
  "category": "Motor vehicles",
  "product": "Motorcycle",
  "brand_as_notified": "Suzuki",
  "brands": [
    {
      "name": "Suzuki",
      "url": "https://recallarchive.com/brand/suzuki"
    }
  ],
  "name": "GSX1300R (HAYABUSA)",
  "model": "e6*168/2013*00077*00 (WEJ0)",
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "Motorcycle.",
  "production_dates": "25.12.2020 - 30.08.2024",
  "risk_type": "Injuries",
  "risk": "Due to an oil additive in the membrane, the primary sleeve in the master cylinder has become swollen and can block the bore. Cooling of the brake fluid can cause a drop in the pressure within the braking system, leading the brake-calliper pistons to be drawn inwards. This can cause greater play in the brake lever. The brake lever can come into contact with the throttle, resulting in an increase in braking distance. This can increase the risk of accidents and injuries. The product does not comply with the Regulation on the approval and market surveillance of two- or three-wheel vehicles and quadricycles.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Recall of the product from end users",
      "operator": "Importer",
      "ordered": false,
      "from": null
    }
  ],
  "measures_as_published": "Type of economic operator taking notified measure(s): Importer\nCategory of measure(s): Recall of the product from end users\nDate of entry into force: Unknown",
  "company_recall_code": "97JU",
  "recall_page": "https://motorrad.suzuki.de/informationen-und-service/offene-rueckrufaktionen",
  "online_marketplaces": [],
  "notifying_country": "Germany",
  "country_of_origin": "Japan",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [
      "97JU"
    ],
    "batches": [
      "25.12.2020 - 30.08.2024"
    ],
    "models": [
      "e6*168/2013*00077*00 (WEJ0)"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}