  "alert_number": "A12/0633/19",
  "url": "https://recallarchive.com/alert/a12-0633-19",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/363256",
  "safety_gate_published": "2019-04-11",
  "weekly_report": {
    "year": 2019,
    "week": 16,
    "date": "2019-04-19"
  },
  "category": "Lighting equipment",
  "product": "Portable LED lamp/torch",
  "brand_as_notified": "Unknown",
  "brands": [],
  "name": "LED EMERGENCY LAMP / LED vészhelyzeti lámpa",
  "model": "NJ-830",
  "batch": "8 002612 002948",
  "barcode_as_notified": null,
  "barcodes": [
    "8002612002948"
  ],
  "description": "Rechargeable torch with a battery charger that can be connected directly to the mains. Packaging: colourful cardboard box.",
  "production_dates": null,
  "risk_type": "Burns, Electric shock, Fire",
  "risk": "The lamp cover can be removed easily during charging and live parts may become accessible. The dimensions of the socket outlet and the flat plug are not adequate. Users may therefore receive an electric shock. The cross-sectional area of the internal and external cores is too small and the wires may overheat. User may consequently suffer burns or the product may cause a fire.The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Withdrawal of the product from the market",
      "operator": "Distributor",
      "ordered": true,
      "from": "13 Feb 2019"
    },
    {
      "measure": "Recall of the product from end users",
      "operator": "Distributor",
      "ordered": true,
      "from": "13 Feb 2019"
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Distributor\nCategory of measure(s): Withdrawal of the product from the market\nDate of entry into force: 13/02/2019\nType of economic operator to whom the measure(s) were ordered: Distributor\nCategory of measure(s): Recall of the product from end users\nDate of entry into force: 13/02/2019",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Hungary",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [
      "8 002612 002948"
    ],
    "models": [
      "NJ-830"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}