  "alert_number": "A12/1388/17",
  "url": "https://recallarchive.com/alert/a12-1388-17",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/281156",
  "safety_gate_published": "2017-10-04",
  "weekly_report": {
    "year": 2017,
    "week": 41,
    "date": "2017-10-13"
  },
  "category": "Electrical appliances and equipment",
  "product": "Computer power supply",
  "brand_as_notified": "Unknown",
  "brands": [],
  "name": "Replacement AC Adapter",
  "model": "ADP-40MH",
  "batch": "4743308108790",
  "barcode_as_notified": null,
  "barcodes": [
    "4743308108790"
  ],
  "description": "Computer power supply, sold in a brown cardboard box.",
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "null The electrical insulation is not sufficient. The clearance /creepage distances between the primary windings and the accessible output connector are not sufficient.The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60950.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Recall of the product from end users",
      "operator": "Distributor",
      "ordered": true,
      "from": "8 Aug 2017"
    },
    {
      "measure": "Withdrawal of the product from the market",
      "operator": "Distributor",
      "ordered": true,
      "from": "8 Aug 2017"
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Distributor\nCategory of measure(s): Recall of the product from end users\nDate of entry into force: 08/08/2017\nType of economic operator to whom the measure(s) were ordered: Distributor\nCategory of measure(s): Withdrawal of the product from the market\nDate of entry into force: 08/08/2017",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Finland",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [
      "4743308108790"
    ],
    "models": [
      "ADP-40MH"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}