  "alert_number": "A12/1424/16",
  "url": "https://recallarchive.com/alert/a12-1424-16",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/232750",
  "safety_gate_published": "2016-10-28",
  "weekly_report": {
    "year": 2016,
    "week": 44,
    "date": "2016-11-04"
  },
  "category": "Lighting equipment",
  "product": "Light",
  "brand_as_notified": "Asa",
  "brands": [
    {
      "name": "Asa",
      "url": "https://recallarchive.com/brand/asa"
    }
  ],
  "name": "LED SUN MAGIC BALL / Rivaldafény",
  "model": "REF: 10545",
  "batch": "5 995858 105456",
  "barcode_as_notified": null,
  "barcodes": [
    "5995858105456"
  ],
  "description": "Mains operated light with 3 rotating LEDs and 48 fixed LEDs (red, blue and green). Packaging: colourful cardboard box.",
  "production_dates": null,
  "risk_type": "Electric shock, Fire",
  "risk": "null The cross-sectional area of the external and internal wires is too small and the wires could overheat. Live parts can be touched when the flat plug is plugged into the mains since the dimensions of the flat plug are not suitable. The wire ends soldered to the terminals of the rectifier unit are not adequately protected against pulling and twisting. As a consequence, the cable could become loose causing accessible parts to become live.The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Withdrawal of the product from the market",
      "operator": "Other",
      "ordered": true,
      "from": null
    },
    {
      "measure": "Recall of the product from end users",
      "operator": "Other",
      "ordered": true,
      "from": "20 Sep 2016"
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Other\nCategory of measure(s): Withdrawal of the product from the market\nDate of entry into force: Unknown\nType of economic operator to whom the measure(s) were ordered: Other\nCategory of measure(s): Recall of the product from end users\nDate of entry into force: 20/09/2016",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Hungary",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [
      "5 995858 105456"
    ],
    "models": [
      "REF: 10545"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}