  "alert_number": "A12/1523/14",
  "url": "https://recallarchive.com/alert/a12-1523-14",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/129920",
  "safety_gate_published": "2014-09-25",
  "weekly_report": {
    "year": 2014,
    "week": 39,
    "date": "2014-10-03"
  },
  "category": "Electrical appliances and equipment",
  "product": "Battery charger",
  "brand_as_notified": "Unknown",
  "brands": [],
  "name": "3G Universal Charger",
  "model": "BC-18",
  "batch": "None",
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "Battery charger with USB power supply. Rated Input: 100-240V, rated output: DC 4.2V, USB output: DC 5.0V. The product is supplied in a cardboard box.",
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "null The product does not provide adequate protection against electric shock because the clearance distance between the primary and secondary circuits is not sufficient.  The transformer is poorly constructed and is not adequately insulated.  The mains pins are loose and could be extended from their sheathing.  The earth pin dimensions are too wide and there is no fuse protection.  The product does not comply with the requirements of the Low Voltage Directive and the relevant European standards EN 60335 and EN 60950.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Import rejected at border",
      "operator": "Other",
      "ordered": true,
      "from": "20 Jun 2014"
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Other\nCategory of measure(s): Import rejected at border\nDate of entry into force: 20/06/2014",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "United Kingdom",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [
      "None"
    ],
    "models": [
      "BC-18"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}