  "alert_number": "A12/1955/19",
  "url": "https://recallarchive.com/alert/a12-1955-19",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/397609",
  "safety_gate_published": "2019-12-05",
  "weekly_report": {
    "year": 2019,
    "week": 50,
    "date": "2019-12-13"
  },
  "category": "Electrical appliances and equipment",
  "product": "USB power supply",
  "brand_as_notified": "Unknown",
  "brands": [],
  "name": "USB 1A and USB Universalna 1A biala",
  "model": "GTIN 5901737937742 and GTIN 5901737246042",
  "batch": "59017372460425901737937742",
  "barcode_as_notified": null,
  "barcodes": [
    "5901737246042",
    "5901737937742"
  ],
  "description": "White plastic USB power supply unit. The product is sold in a plastic film with two stickers printed in Polish. Details of the power supply unit: Input: 100-240V of 50/60Hz and 0.15 A Output: 5V and 1A .",
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "The suppression capacitor between the mains primary and USB secondary circuits is not strong enough. Consequently, the accessible USB port becomes live increasing the risk of electric shock.The product does not comply with the Low Voltage Directive and the relevant European standard EN 62368-1.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Recall of the product from end users",
      "operator": "Other",
      "ordered": true,
      "from": "27 Nov 2019"
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Other\nCategory of measure(s): Recall of the product from end users\nDate of entry into force: 27/11/2019",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Germany",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [],
    "batches": [
      "5901737246042",
      "5901737937742"
    ],
    "models": [
      "GTIN 5901737937742 and GTIN 5901737246042"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}