  "alert_number": "SR/00222/25",
  "url": "https://recallarchive.com/alert/sr-00222-25",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/10092664",
  "safety_gate_published": "2025-01-09",
  "weekly_report": {
    "year": 2025,
    "week": 3,
    "date": "2025-01-17"
  },
  "category": "Electrical appliances and equipment",
  "product": "LED flashlight",
  "brand_as_notified": "ARMYTEK",
  "brands": [
    {
      "name": "Armytek",
      "url": "https://recallarchive.com/brand/armytek"
    }
  ],
  "name": "Rechargeable LED flashlight",
  "model": "VIKING PRO",
  "batch": null,
  "barcode_as_notified": "4894128144977",
  "barcodes": [
    "4894128144977"
  ],
  "description": "Rechargeable LED flashlight. Luminaire: class III.Power supply unit: 110-240V, 5VDC / 2A, class I. Product sold online, in particular via armytek.fi.",
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "The electrical insulation and the creepage distance between the primary and secondary circuits are not sufficient (measured value: 0.3 mm). A user could receive an electric shock from accessible live parts from the battery charger. The product does not comply with the requirements of the Low Voltage Directive nor with the European standard EN 61558.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Recall of the product from end users",
      "operator": "Importer",
      "ordered": true,
      "from": "12 Sep 2024"
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Importer\nCategory of measure(s): Recall of the product from end users\nDate of entry into force: 12/09/2024",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Finland",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [
      "4894128144977"
    ],
    "batches": [],
    "models": [
      "VIKING PRO"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}