  "alert_number": "SR/01388/26",
  "url": "https://recallarchive.com/alert/sr-01388-26",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/10098845",
  "safety_gate_published": "2026-05-07",
  "weekly_report": {
    "year": 2026,
    "week": 19,
    "date": "2026-05-15"
  },
  "category": "Motor vehicles",
  "product": "Passenger car",
  "brand_as_notified": "Aston Martin",
  "brands": [
    {
      "name": "Aston Martin",
      "url": "https://recallarchive.com/brand/astonmartin"
    }
  ],
  "name": "DBX, DBX707, DBX S, DBX Straight-six",
  "model": "AM8, AM8SS, e9*2007/46*6804*00-*03, e9*KS18/858*11438*00-*04",
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "Passenger car.",
  "production_dates": "27.02.2020 - 05.11.2025",
  "risk_type": "Injuries",
  "risk": "A bolt with a reduced shank diameter could cause the torque pin to slide out of the rear lower suspension arm. This may lead to overload and failure of the lower suspension arm, which can cause damage to other suspension components and the rear brakes, which could cause an accident. The product does not comply with the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Recall of the product from end users",
      "operator": "Other",
      "ordered": false,
      "from": "27 Apr 2026"
    }
  ],
  "measures_as_published": "Type of economic operator taking notified measure(s): Other\nCategory of measure(s): Recall of the product from end users\nDate of entry into force: 27/04/2026",
  "company_recall_code": "RA-41-2086",
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Germany",
  "country_of_origin": "United Kingdom",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [
      "RA-41-2086"
    ],
    "batches": [
      "27.02.2020 - 05.11.2025"
    ],
    "models": [
      "AM8, AM8SS",
      "e9*2007/46*6804*00-*03, e9*KS18/858*11438*00-*04"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}