  "alert_number": "SR/02158/26",
  "url": "https://recallarchive.com/alert/sr-02158-26",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/10114882",
  "safety_gate_published": "2026-07-30",
  "weekly_report": {
    "year": 2026,
    "week": 31,
    "date": "2026-08-07"
  },
  "category": "Electrical appliances and equipment",
  "product": "Electric incense burner",
  "brand_as_notified": null,
  "brands": [],
  "name": null,
  "model": "WL-05D",
  "batch": null,
  "barcode_as_notified": null,
  "barcodes": [],
  "description": "Electric incense burner. Voltage of 220-240 V. All batches are concerned.",
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "The appliance is not earthed. In addition, its conductors are not held in position, the accessible metal parts are not sufficiently insulated from the live parts, in particular the conductors of the power supply cable, and the clearance /creepage distances between the live parts of the heating element and the accessible metal part are insufficient. The user may therefore touch live parts and receive an electric shock.  The product does not comply with the requirements of the Low Voltage Directive.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Withdrawal of the product from the market",
      "operator": "Importer",
      "ordered": false,
      "from": null
    },
    {
      "measure": "Recall of the product from end users",
      "operator": "Importer",
      "ordered": false,
      "from": "2 Feb 2026"
    }
  ],
  "measures_as_published": "Type of economic operator taking notified measure(s): Importer\nCategory of measure(s): Withdrawal of the product from the market\nDate of entry into force: Unknown\nType of economic operator taking notified measure(s): Importer\nCategory of measure(s): Recall of the product from end users\nDate of entry into force: 02/02/2026",
  "company_recall_code": null,
  "recall_page": "https://rappel.conso.gouv.fr",
  "online_marketplaces": [],
  "notifying_country": "France",
  "country_of_origin": "People's Republic of China",