  "alert_number": "SR/02730/25",
  "url": "https://recallarchive.com/alert/sr-02730-25",
  "official_notice": "https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/10095333",
  "safety_gate_published": "2025-07-18",
  "weekly_report": {
    "year": 2025,
    "week": 30,
    "date": "2025-07-25"
  },
  "category": "Lighting chains",
  "product": "Lighting chain",
  "brand_as_notified": null,
  "brands": [],
  "name": "Christmas lights",
  "model": "XM-100-C-L-LO",
  "batch": null,
  "barcode_as_notified": "6902104579137",
  "barcodes": [
    "6902104579137"
  ],
  "description": "Lighting chain consisting of 100 non-replaceable LED light sources and a device for changing lighting modes.",
  "production_dates": null,
  "risk_type": "Electric shock",
  "risk": "Due to the insufficient mechanical strength of the product, access to live parts is possible. Moreover, the product does not meet the declared requirements for protection against moisture. This may result in the user receiving an electric shock. The product does not comply with the requirements Low Voltage Directive nor with the European standard EN 60598.",
  "risk_level": "Serious risk",
  "measures": [
    {
      "measure": "Recall of the product from end users",
      "operator": "Distributor",
      "ordered": true,
      "from": "4 Jun 2025"
    }
  ],
  "measures_as_published": "Type of economic operator to whom the measure(s) were ordered: Distributor\nCategory of measure(s): Recall of the product from end users\nDate of entry into force: 04/06/2025",
  "company_recall_code": null,
  "recall_page": null,
  "online_marketplaces": [],
  "notifying_country": "Hungary",
  "country_of_origin": "People's Republic of China",
  "alert_type": "Consumer",
  "counterfeit": false,
  "official_record": {
    "barcodes": [
      "6902104579137"
    ],
    "batches": [],
    "models": [
      "XM-100-C-L-LO"
    ]
  },
  "licence": "Weekly-report fields CC0 1.0; official_record and counterfeit: © European Union, CC BY 4.0",
  "source": "EU Safety Gate. recallarchive is independent and not affiliated with the European Commission; the official notice is authoritative."
}