Combined baby bathing/changing unit.
Serious risk Injuries, Suffocation
- Product
- Combined baby bathing/changing unit.
- Description
- Category: Children’s equipmentProduct: Combined baby bathing/changing unit.Brand: PRENATALType/number of model: Reference 457817
- Risk
- This baby bathing/changing unit presents a serious risk of trapping various parts of a child's body and the risk of choking because:- there are holes which permit entry of the 5 mm gauge with a force of less than 30 N, but not of the 12 mm gauge;- there are holes which permit entry of the 25 mm gauge with a force of less than 30 N but do not permit entry of the 45 mm gauge;- the gap remaining between the changing table (when open) and the edge of the bath permits entry of the 45 mm gauge with a force of less than 30 N and does not permit entry of the 65 mm gauge;- the changing unit folds with a force of less than 200 N, with the consequent risk of injury to the child;- during the test the plastic button on the underside of the changing table became detached with a traction force of less than 90 N, producing a small part which could give rise to choking.This product does not comply with the relevant European standard EN 12221.
- Measures
- Withdrawal from the market ordered by the authority
- Notifying country
- Spain
- Country of origin
- Italy
- Alert type
- Consumer
- Photos
- Photos shown from the Safety Gate server (European Commission); not copied here.
This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.