Skip to content

Computer hardware – Netgear

Serious risk Fire

Published by Safety Gate 17 Jan 2008In the weekly report of 18 Jan 2008 (week 2, 2008)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 2 min agoSource: EU Safety Gate
Product
Computer hardware
Brand
Netgear
Brand as notified
NETGEAR
Type / model
NETGEAR XE103 (sold individually or as part of a bundled kit). Model numbers affected (including bundled kits):XE103-100AUS, FSS, GRS, ISS, UKS, NAS. XE103-100AUB, ISB, UKB, NAB. XE103-100NAR.XE103G-100FRS, FSS, GRS, ISS, UKS. XE104G-100FSS, UKS. XEPSB103-100AUS, GRS, ISS, UKS.
Description
The XE103 is an Ethernet adaptor that uses house wiring to implement a local area network. When used in pairs, the XE103 transmits and receives Ethernet data up to 85Mbs. The XE103 is equipped with one RJ45 Ethernet connector.
Risk
The product poses a serious risk of fire because the power supply integrated circuit (IC) within the XE103 may fail. Such IC failure may cause another component, called a Polyswitch, which is used to limit the current delivered to the product, to also fail. When the Polyswitch fails, it releases a small amount of smoke and soot and a visible flash of light. The duration of this is approximately 3 seconds and does not produce flaming combustion or glowing embers that escape the enclosure. This event does not pose a risk to surrounding light combustible material or a safety hazard to a user. However, on the basis of the external testing that has been carried out, it cannot be ruled out that a very small number of units that experience a Polyswitch failure may also experience a more severe failure, if a conduction path is established between the two unprotected solder nodes that connect AC power to the printed circuit board. If this occurs, light combustible materials surrounding the product may ignite.
Measures
  • Voluntary corrective actions taken by the manufacturer
Notifying country
United Kingdom
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0023/08
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert 0023/08
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2008-2 (XML)
    the copy this page was built fromCC0 1.0