Skip to content

Electrical appliances and equipment

Serious risk Electric shock

Published by Safety Gate 24 Feb 2005In the weekly report of 25 Feb 2005 (week 8, 2005)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 5 min agoSource: EU Safety Gate
Description
Three and six sockets extension supply cords with switches “Zhong Ya”.
Risk
Risk of electric shock. Unsafe soldering and wires fixation; insufficient wires section; incorrectly marked. The extension supply cords do not comply with the Low Voltage Directive and the relevant European standards.
Measures
  • Placing on the market prohibited by the authorities
Notifying country
Germany
Country of origin
Unknown
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0079/05Photo 2 of the product in Safety Gate alert 0079/05Photo 3 of the product in Safety Gate alert 0079/05Photo 4 of the product in Safety Gate alert 0079/05Photo 5 of the product in Safety Gate alert 0079/05
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert 0079/05
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2005-8 (XML)
    the copy this page was built fromCC0 1.0