Skip to content

Electrical appliances and equipment – QE7

Serious risk Fire

Published by Safety Gate 14 Apr 2005In the weekly report of 15 Apr 2005 (week 15, 2005)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked just nowSource: EU Safety Gate
Brand
QE7
Brand as notified
QE7.
Description
Electric water heating timing device (in homes).Brand: QE7. Name: Grässlin QE7 Timer.Type/model: QE7.
Risk
Risk of fire. Overheating in a small number of the products can be caused by high resistance contacts on the clamp connections due to premature relaxation of the metal clamps.The timing device does not comply with the Low Voltage Directive.
Measures
  • Placing on the market voluntarily stopped and product recall from consumers
Notifying country
Ireland
Country of origin
Germany
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0189/05
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert 0189/05
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2005-15 (XML)
    the copy this page was built fromCC0 1.0