Skip to content

Communication and media equipment

Serious risk Electric shock

Published by Safety Gate 4 May 2006In the weekly report of 5 May 2006 (week 17, 2006)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 2 min agoSource: EU Safety Gate
Type / model
UHD 3500
Barcode
4040895184153
Barcodes listed
4040895184153 (official alert record)
Description
Computer hard disk drive "Ultron" (mains unit of an external HDD drive)
Risk
Product poses a risk of electric shock because: -there is a heightened risk of flashover of the 240V supply to the low-voltage side which would expose the user to a lethal voltage;-the insulation separating the primary and secondary coils of the transformer is inadequate; -the ground conductor connection is too small and not secured against coming loose.Product does not comply with the LVD and the relevant European standard EN 60950.
Measures
  • Voluntary recall of the product from the market by the producer
Notifying country
Germany
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0245/06
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.