Recessed luminaire – Brilux
Serious risk Electric shock, Fire
- Product
- Recessed luminaire
- Brand
- Brilux (7 alerts)
- Brand as notified
- BRILUX
- Type / model
- 7000A. Bar code: 5 905148 007919
- Description
- The metal-covered luminaire provided with a glass plate consists of a metal frame and a non-adjustable mirror + a fitting unit fixed to the frame with riveting. The fitting unit includes two G24d-3 plastic lampholders and a terminal block. There is a decorative glass plate fitted to the luminaire. Main components: lampholder ("CQC CE 2A 250V"), terminal block ("TEILBAR 500 400V 2,5-4 CE" + mark of approval), internal wiring ("H05S-K 1x0.75 mm2 VDE"). Technical specifications: 230 V; 50 Hz; PLC 2x26 W G24d-3; Class I; F-mark, IP 20.
- Risk
- The product poses risk of :- electric shock because the basic-insulated parts (terminal block, single insulated wire) on the external surface of the luminaire are accessible, - fire since the instruction manual does not contain the type of lamp control-gear and its distance from the luminaire recommended by the manufacturer. There is no warning in the instruction manual that the luminaire may only be connected to the power supply through a proper lamp control.The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
- Measures
- Withdrawal from the market and recall from consumers ordered by the authorities
- Notifying country
- Hungary
- Country of origin
- People's Republic of China
- Alert type
- Consumer
- Photos
- Photos shown from the Safety Gate server (European Commission); not copied here.
This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.
Other alerts for Brilux
- Lighting equipment · Hungary Built-in spotlight – Brilux “"Pont lámpatest, stabil" (still spotlight)” 19 Sepweek 37 report, 2014 Electric shock Serious risk
- Lighting equipment · Hungary Recessed luminaire – Brilux 11 Aprweek 14 report, 2008 Electric shock, Fire Serious risk
- Lighting equipment · Hungary Recessed luminaire – Brilux 21 Marweek 11 report, 2008 Electric shock Serious risk
- Lighting equipment · Hungary Recessed luminaire – Brilux 21 Marweek 11 report, 2008 Electric shock, Fire Serious risk
- Lighting equipment · Hungary Recessed luminaire – Brilux 21 Marweek 11 report, 2008 Electric shock Serious risk
- Lighting equipment · Hungary Recessed luminaire – Brilux 21 Marweek 11 report, 2008 Electric shock Serious risk