Skip to content

Table lamp (TOMI) – Szarvas

Serious risk Electric shock, Fire

Published by Safety Gate 19 Apr 2007In the weekly report of 20 Apr 2007 (week 15, 2007)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 3 min agoSource: EU Safety Gate
Product
Table lamp (TOMI)
Brand
Szarvas
Type / model
DSL-010 B-65
Risk
This product poses a risk of electric shock because:- the insulation of the internal wiring may get damaged due to the presence of burry metal edges;- the protecting plastic tubes are not fixed, thus they can move at the lamp shade and the basic insulated wires can get into contact with accessible metal cover;- the cross section area is less than required. This product poses a risk of fire because the luminaire tipped over on a standard slope which may entail the overheating of the supporting surface.This product does not comply with the Low Voltage Directive and the relevant European standards.
Measures
  • Withdrawal from the market, recall from consumers and information to consumers ordered by the authorities
Notifying country
Hungary
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0354/07Photo 2 of the product in Safety Gate alert 0354/07
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert 0354/07
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2007-15 (XML)