Skip to content

Lighting equipment

Serious risk Electric shock

Published by Safety Gate 13 Jul 2006In the weekly report of 14 Jul 2006 (week 27, 2006)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 5 min agoSource: EU Safety Gate
Type / model
MA5070
Description
Tent light "Sunnflair" 230V.
Risk
This product poses a risk of electric shock because:- There is access to live parts when globe removed in normal use to replace lamp. - Cord anchorage of supply cable is inadequate; it is achieved by knot tied in cable inside lamp globe.- Mechanical strength of the mains supply cable is inadequate; cross sectional area is 0.5mm2 compared with the required 1.0mm2. This product does not comply with the LV Directive and the European Standard 60598-2-4:1998.
Measures
  • Voluntary recall from consumers by the importer
Notifying country
United Kingdom
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0420/06Photo 2 of the product in Safety Gate alert 0420/06
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.