Skip to content

Electrical appliances and equipment

Serious risk Electric shock

Published by Safety Gate 3 Aug 2006In the weekly report of 4 Aug 2006 (week 30, 2006)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 1 min agoSource: EU Safety Gate
Barcode
8711295422300
Barcodes listed
8711295 422300 (official alert record)
Barcode as notified
8711295 422300
Description
Electric Insect KillerDescription: Unknown
Risk
This product poses a risk of electric shock because:- live parts with a dangerous charge (68,0VACpeak) are accessible with the test finger, - charge of accessible live parts (52,9μC) exceeds limit indicated in the standard (45μC),- leakage current of 126 mApeak is too high (0,25mApeak is required by the standard) and is accessible.This product does not comply with the Low Voltage Directive and LVD Standard.
Measures
  • Placing of the product on the market voluntarily suspended. Voluntary recall from consumers
Notifying country
The Netherlands
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0466/06
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert 0466/06
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2006-30 (XML)
    the copy this page was built fromCC0 1.0