Description
Floor standing electrical lamp “Hangzhou Delta Art Light Co Ltd. - Fiorentina Lamp”
Risk
1) The luminaire has inadequate protection against electric shock. - The luminaire contains two lampholders. The wiring for these lampholders is connected to the supply cord by crimped terminals which are partially covered with some heat shrinkable sleeving. However, the test finger can touch the basic insulation covering the conductors. The Standard requires that the test finger should not be able to touch parts that were not separated by at least two levels of insulation or their equivalent. - The basic insulation on the internal wires is touching the metal parts of the luminaire. Thus the test finger can also touch accessible conductive parts separated from live parts by only a single layer of insulation. The metal frame would become live should the insulation fail. 2) The terminals are not satisfactorily crimped onto the conductors. The metal insert within the crimp is simply flattened onto the conductors and not permanently crimped. The neutral terminal can be easily pulled from the conductors. Poor terminations can lead to overheating. 3) This sample does not meet the marking requirements of the standard. This product does not comply with the LVD standards.
Measures
  • Withdrawal from the market ordered by the authority
Notifying country
United Kingdom
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0469/06Photo 2 of the product in Safety Gate alert 0469/06
Photos shown from the Safety Gate server (European Commission); not copied here.