Skip to content

Electrical appliances and equipment

Serious risk Electric shock, Fire

Published by Safety Gate 28 Sep 2006In the weekly report of 29 Sep 2006 (week 38, 2006)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 9 min agoSource: EU Safety Gate
Type / model
GTM-116
Description
Coffee maker "PERLA"
Risk
The product was examined according to the requirements of the Low voltage Directive 73/23/EEC and has been found in non-compliance with the requirements of the applicable standards because:a) The rise of temperature at inner wiring was 129 K, with upper limit 50 K (risk of fire)b) During the test the resistant melted and touched the plastic base of the appliance (risk of fire)c) The earth cable conduit is shorter than the current ones (risk of electric shock)
Measures
  • Voluntary actions taken by the importer: withdrawal from the market, recall from consumers and information to consumers
Notifying country
Greece
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0605/06
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert 0605/06
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2006-38 (XML)
    the copy this page was built fromCC0 1.0