Fibre optic device "Fast Ethernet converter" – N-Net Technology

Serious risk Electric shock

Published by Safety Gate 12 Jun 2008In the weekly report of 13 Jun 2008 (week 23, 2008)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked just nowSource: EU Safety Gate
Product
Fibre optic device "Fast Ethernet converter"
Brand
N-Net Technology
Brand as notified
N-NET TECHNOLOGY
Type / model
NT-S1200
Description
Fibre optic device. Grey box marked with "N-net" in orange and red. "10/100 Base-TX to 100 Base-FX Fast Ethernet Converter" in white.
Risk
The product poses a risk of electric shock because :(i) Model Class I :- the creepage and clearance distances are too short on the power supply : Primary foil– Secondary foil = 1.7mm (min. req. 5.0mm), Primary foil – Earth foil = 1.3mm (min. req. 2.5mm).- Class II plug connected to Class I outlet without safety earth wire in theCable.(ii) Model Class II :- the creepage and clearance distances are too short on the power supply: Primary foil – Secondary foil= 1.2mm (min. req. 5.0mm), Primary – Chassis = 0.2mm (min. req. 5.0mm) (between capacitor CX2 – chassis).- electrical strength test Pri-Chassis / 3000V (Failed at 600V).The product does not comply with the Low Voltage Directive and the relevant European standards EN 60950 and EN 60065.
Measures
  • Withdrawal from the market and recall from consumers ordered by the authorities
Notifying country
Sweden
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0622/08
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert 0622/08
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2008-23 (XML)
    the copy this page was built fromCC0 1.0