Lighting chains
Serious risk Electric shock
- Type / model
- 1. R160+, 2. R200+
- Description
- “JÉGCSAPÉGŐ”(CEDAR) 1. 160 non-replaceable miniature incandescent lamps + an 8-function flashing unit; 2. 200 non-replaceable miniature incandescent lamps + an 8-function flashing unit.Description: The lighting chains consist of 160/200 series-parallel connected incandescent lamps with resistor bridge. The flashing unit controls 4 parallel-connected circuits for flashing the non-replaceable light sources. Main parts of the lighting chains: bipolar plug with inscription: “CH 2.5 A 250 V~ TS-01 VDE”; flashing unit with inscriptions: “FLASHER CONTROL UNIT 220V AC 50HZ 0.83A PRESS” + names of functions. Technical specifications: 230V; 50Hz; 5 V; 0,068 mA; 55W/68W; by appearance Class II, IP20.
- Risk
- The products pose a risk of electric shock because:- the insulation of the wires does not meet the requirements of the standard;- the PVC insulated wires are not suitable for outdoor use;- the flashing unit, the plug, the sockets and the connections of lamp wires are not protected against ingress of water;- the light sources have insufficient (single) insulation;- the cross section area of the wires is less than required;- the wire inlets of the flashing unit are sharp, thus the wires can get damaged;- the wires are not fixed against loosening. These products do not comply with the Low Voltage Directive and the relevant EN standard 60598.
- Measures
- Sales ban ordered by the authority
- Notifying country
- Hungary
- Country of origin
- People's Republic of China
- Alert type
- Consumer
- Photos
- Photos shown from the Safety Gate server (European Commission); not copied here.
This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.