Desk lamp with E12 capped candle incandescent lamp

Serious risk Electric shock

Published by Safety Gate 12 Jul 2007In the weekly report of 13 Jul 2007 (week 27, 2007)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 7 min agoSource: EU Safety Gate
Product
Desk lamp with E12 capped candle incandescent lamp
Brand
Unknown
Type / model
No B-17 F
Description
The cover of the luminary is made of glass plates of various sizes placed into wooden frames. The glass is decorated with different motifs. The frames are fixed with screws on the bottom and upper part. The bottom profile part is fitted with the E12 lampholder to which the cord switch and the mains cable is connected. Main parts of the luminary: mains cable (SANTORY; 300V; 70°C; PVC; VFF; 2x0.6 SQ.MM.; TABLE; 10; TIS; 11-2531; A.R.C.); mains plug (KTR-1991); cord switch (SANTORY; SP-109; 6A; 250V); unipolar switch built into the cord switch (LG; 6A; 250V; TÜV; CE); E12 lampholder (SANTORY; LH-12A; 250V; 7W). Technical specification: there is no data plate, Class II by appearance.
Risk
The product poses a serious risk of electric shock because:- live parts of the lamp-head are accessible;- the plug is of non-standardized type;- there is no cord anchorage protecting against the pulling and twisting force, and it can contact with sharp edges, thus the cable may get damaged. The product does not comply with the Low Voltage Directive and the relevant European standards EN 60598 and EN 60238.
Measures
  • Withdrawal from the market and recall from consumers ordered by the authorities
Notifying country
Hungary
Country of origin
Thailand
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0652/07
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert 0652/07
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2007-27 (XML)
    the copy this page was built fromCC0 1.0