Skip to content

Lighting equipment

Serious risk Electric shock

Published by Safety Gate 15 Dec 2005In the weekly report of 16 Dec 2005 (week 50, 2005)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 7 min agoSource: EU Safety Gate
Description
Outdoor fixed luminaire "MB 307-1" (230 V; max 60 W; Class I; lamp holder: E27).Type/model: Unknown.
Risk
Live terminals and basic insulated wires of the lamp become accessible by the standard test finger. The 'wireways' are lead through sharp edges, thus the wires may become damaged. If the wires of the stranded conductor are released, contact between the accessible metal parts of the lamp and the live wires of the cable is possible what may cause electric shock.The lamp does not comply with the LVD Directive and the European Standards.
Measures
  • Withdrawal from the market and prohibition of distribution ordered by the authority
Notifying country
Hungary
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0653/05
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert 0653/05
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2005-50 (XML)
    the copy this page was built fromCC0 1.0