Skip to content

Lighting equipment

Serious risk Electric shock, Fire

Published by Safety Gate 22 Dec 2005In the weekly report of 23 Dec 2005 (week 51, 2005)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked just nowSource: EU Safety Gate
Description
Snail-formed luminaire "Tiffany"Type/model: TK-717; 230V~ rated voltage
Risk
The mains cable provided with a switch is directly connected to the lamp holder. The luminaire assemble has only basic insulation and the wires are accessible by the standard test finger. If the insulation get damaged electric shock may occur. The cord anchorage is not appropriate. The dimensions of the plug do not comply with the standard. The temperature of the internal PVC wire was 79,1°C (while the maximum value is: 75°C).
Measures
  • Withdrawal from the market and placing on the market prohibited by the authority
Notifying country
Hungary
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0673/05
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert 0673/05
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2005-51 (XML)
    the copy this page was built fromCC0 1.0