Lighting equipment

Serious risk Electric shock, Fire, Injuries

Published by Safety Gate 26 Oct 2006In the weekly report of 27 Oct 2006 (week 42, 2006)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 2 min agoSource: EU Safety Gate
Type / model
LT100
Barcode
4004712977045
Barcodes listed
4004712977045 (official alert record)
Description
Portable luminaire for children “Hartig & Hellig“
Risk
This product poses a risk of electric shock and injury because:- the luminaire fails the test with spring-operated hammer (with impact energy of 0,7Nm) and ‘fall test’ (height 850mm); in both cases lampshade becomes detached; - during the tests, accessible parts of the lamp reach temperature of 118° C (maximum allowed temperature for accessible non-metallic parts is 75° C); - connector for adaptor 12 Va.c. fails the ball-pressure test at 125° C;- measured diameter of impression is 5mm (maximum allowed diameter of impression is 2mm).This product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
Measures
  • Sales ban ordered by the authority
Notifying country
Slovenia
Country of origin
Germany
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0679/06
Photos shown from the Safety Gate server (European Commission); not copied here.