Skip to content

Lighting chain "LED-Háló karácsonyi ég" – Ante

Serious risk Electric shock, Fire

Published by Safety Gate 27 Apr 2012In the weekly report of 4 May 2012 (week 18, 2012)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 7 min agoSource: EU Safety Gate
Product
Lighting chain "LED-Háló karácsonyi ég"
Brand
Ante (15 alerts)
Type / model
DCH (on packaging)
Batch
5 999048 633712
Barcode
5999048633712
Description
Lighting chain with 40 serial connected, non-replaceable LED lamps.
Risk
null The product poses a risk of electric shock and fire because:·         The cross-sectional area of the wires is not sufficient and the wires can consequently overheat.·         The wire ends soldered to the rectifying unit terminals and the LEDs are not adequately protected against pulling and twisting. ·         The accessible wires have only basic insulation and if they come into contact with the sharp edges of the rectifying unit live wires can become accessible. The product does not comply with the Low Voltage Directive (LVD) and the relevant European standard EN 60598.
Notifying country
Hungary
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0682/12Photo 2 of the product in Safety Gate alert 0682/12
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Other alerts for Ante

Sources

  1. Safety Gate alert 0682/12
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2012-018 (XML)
    the copy this page was built fromCC0 1.0