Skip to content

AC adaptor for TFT television/monitor “Denver” (television itself is not affected)

Serious risk Electric shock

Published by Safety Gate 23 Nov 2006In the weekly report of 24 Nov 2006 (week 46, 2006)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 7 min agoSource: EU Safety Gate
Product
AC adaptor for TFT television/monitor “Denver” (television itself is not affected)
Type / model
FJ-SW1210X
Barcode
5700751005299
Barcodes listed
5 700751 005299 (official alert record)
Barcode as notified
5 700751 005299
Risk
The product poses a serious risk of electric shock because: - the insulation between the parts connected to the mains (primary circuit) and parts that can be touched by the user (secondary circuit) is not sufficient. In particular: - creepage distances and clearances in the mains transformer between the primary windings and secondary windings are less than 5mm/4 mm (measured a minimum of 0.4 mm); - the secondary circuit is accessible through the terminals. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60065.
Measures
  • Withdrawal from the market and recall from consumers ordered by the authority
Notifying country
Finland
Country of origin
Unknown
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0753/06
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert 0753/06
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2006-46 (XML)
    the copy this page was built fromCC0 1.0